Hydraulic Fittings Glossary: BSP, JIC, ORFS, Metric, NPT & Common Connection Terms
Hydraulic fittings connect hoses, rigid tube, pipework, valves, cylinders, pumps and other components within hydraulic systems. Correct identification matters because fittings that look similar may use different threads, sealing methods, seat forms and dimensions — and may not be interchangeable.
Updated: 7 October 2026
Quick Answer: What Is a Hydraulic Fitting?
A hydraulic fitting is a connection component used to join hydraulic hoses, tube, pipework or equipment. Correct selection depends on more than thread diameter: the thread type, pitch, size, sealing method, seat form, pressure capability, material and compatibility with the rest of the hydraulic system all need to be considered.
Get Priority Hydraulic Support & Trade Pricing
Jump the queue. Reduce downtime. Pay less for parts, labour and callouts.
✔ Priority response
✔ Lower rates day & night
✔ Trade discounts on parts
✔ 30-day credit terms (approved accounts)
Why Hydraulic Fitting Identification Matters
A connection that screws together is not necessarily the correct connection.
Hydraulic fittings can differ in:
- Thread form
- Thread pitch
- Parallel or tapered thread
- Seat angle and shape
- O-ring location
- Nominal size
- Sealing method
- Pressure capability
- Material
- Application standard
Do Not Identify a Fitting by Thread Diameter Alone
Two fittings can appear very similar while using different thread pitches, seat forms or sealing methods. Positive identification should consider the complete connection rather than simply measuring the outside diameter of the thread.
Common Hydraulic Fitting Types: Quick Reference
| Connection | Key Feature | Typical Sealing Principle |
|---|---|---|
| BSPP | Parallel BSP thread | Depends on connection design; may use a sealing face, bonded seal or other dedicated seal |
| BSPT | Tapered BSP thread | Thread-based sealing arrangement according to the connection specification |
| JIC | 37° flare connection | Metal-to-metal flare/seat |
| ORFS | Flat face with O-ring | O-ring face seal |
| Metric / DIN | Metric connection families | Varies with the particular connection design |
| NPT | Tapered pipe thread | Thread interference/sealing arrangement |
| Flange | Flanged hydraulic connection | Typically dedicated sealing element within the flange connection |
BSP — British Standard Pipe
BSP is a commonly encountered connection family in UK hydraulic equipment. Importantly, BSP should not be described simply as a parallel thread because both parallel and tapered forms exist.
BSPP
BSPP uses a parallel thread. Depending on the fitting design, the hydraulic seal may be created using a sealing face, bonded seal or another dedicated sealing arrangement rather than by the parallel thread itself.
BSPT
BSPT uses a tapered thread. Its sealing principle differs from a typical BSPP connection.
BSPP and BSPT Are Not the Same Thing
Always identify whether the connection is parallel or tapered and determine the actual sealing arrangement before selecting a replacement fitting or adapter.
JIC — 37° Flare Fitting
JIC hydraulic connections use a 37-degree flare sealing surface.
The important point is that the hydraulic seal is produced at the mating flare and seat surfaces — not by the threads themselves. The threads draw the mating surfaces together.
Damage, contamination or deformation at the sealing surfaces can therefore cause leakage even when the threads appear serviceable.
ORFS — O-Ring Face Seal
ORFS stands for O-Ring Face Seal.
The connection uses an O-ring located at the face of the fitting to create the hydraulic seal when the mating components are correctly assembled.
When inspecting an ORFS connection, the condition of the O-ring and sealing faces is therefore important. A damaged, contaminated, hardened or unsuitable seal can contribute to leakage.
Metric & DIN Hydraulic Fittings
Metric hydraulic connections are widely encountered on European machinery and industrial equipment.
However, the description “metric fitting” is not enough to positively identify a connection. Metric hydraulic systems include different thread sizes, pitches, sealing arrangements and connection designs.
Correct identification should therefore consider:
- Thread diameter
- Thread pitch
- Male or female connection
- Seat or cone geometry
- Sealing method
- Associated tube or port specification
NPT — National Pipe Thread
NPT is a tapered pipe-thread connection commonly associated with North American equipment and components.
The original version of this glossary described NPT simply as a low-pressure fitting. That is not a reliable way to classify it. Suitability and pressure capability depend on the particular fitting, size, material, manufacturer and application.
NPT and BSP Are Not Interchangeable
Although certain NPT and BSP connections can appear similar, their thread forms and specifications differ. They should not be treated as interchangeable simply because the components appear to screw together.
Hydraulic Flange Connections
Flange connections are used in hydraulic systems where the particular component and application are designed for this style of connection.
They may be encountered on pumps, motors, valves, cylinders and larger hydraulic lines.
Correct flange identification requires the relevant dimensions, pressure series, connection design and sealing arrangement to be established rather than selecting by appearance alone.
Hydraulic Adapter
A hydraulic adapter allows different hydraulic connection types, sizes or orientations to be joined where the adapter is suitable for the system.
Examples include:
- Straight adapters
- Elbows
- Tees
- Reducers
- Bulkhead adapters
- Swivel connections
- Adapters between different connection standards
Avoid Unnecessary Adapter Chains
Every additional connection creates another interface that must be correctly specified, assembled and sealed. Multiple adapters should not be added merely to force incompatible or poorly selected components together.
For more detail see our Hydraulic Fittings & Adapters Guide.
Male & Female Hydraulic Fittings
A male fitting generally has an external thread, while a female fitting generally has an internal thread.
However, male/female identification alone does not establish whether two fittings are compatible.
The thread standard, size, pitch, seat geometry and sealing method must still match the intended connection.
Thread Pitch
Thread pitch describes the spacing of threads. Depending on the thread system, this may be expressed as a distance between threads or as threads per inch.
Thread pitch is an important part of fitting identification because fittings with similar outside diameters may use different pitches.
Parallel Thread vs Tapered Thread
A parallel thread maintains substantially the same diameter along its threaded length.
A tapered thread changes diameter along its threaded length.
The distinction is important because different connection systems use different sealing principles. A parallel threaded connection may rely on a separate sealing surface or sealing element, while certain tapered pipe connections use the thread engagement as part of their sealing arrangement.
Hydraulic Fitting Sealing Methods
Hydraulic fittings do not all seal in the same way.
Flare / Seat
Mating metal surfaces create the seal, as with a correctly matched JIC connection.
O-Ring
An elastomeric sealing element creates the seal at a designed sealing surface.
Bonded Seal
A dedicated sealing washer may be used on appropriate port and fitting designs.
Tapered Thread
Certain pipe-thread connections use tapered thread engagement as part of the sealing arrangement.
Hydraulic Hose Fitting
A hydraulic hose fitting forms the end connection of a hydraulic hose assembly.
Hose and fitting compatibility is critical. A fitting should not be selected simply because it appears to fit the hose.
Use a Compatible Hose & Fitting System
The hose, fitting and assembly specification need to form an approved and validated combination. Components from different systems should not be assumed compatible simply because their dimensions appear similar.
Crimped Hydraulic Hose Fitting
A crimped fitting is permanently attached to a compatible hydraulic hose using appropriate assembly equipment and the specified crimp dimensions for that hose and fitting system.
Correct assembly depends on factors including:
- Correct hose series
- Correct fitting
- Correct preparation
- Correct insertion
- Specified crimp dimensions
- Suitable assembly equipment
- Inspection of the completed assembly
A fitting that is merely capable of being physically inserted into a hose is not evidence that the combination is suitable.
Quick-Release Hydraulic Coupling
A quick-release or quick-connect coupling allows a hydraulic connection to be connected and disconnected using the coupling’s designed mechanism rather than repeatedly dismantling a conventional threaded connection.
Different coupling designs have different pressure, flow, connection, disconnection and application characteristics. The correct coupling must therefore be selected for the hydraulic system and operating conditions.
Hydraulic Fitting Pressure Rating
There is no reliable rule that one fitting family or material automatically has a particular pressure capability.
Pressure suitability can depend on:
- Fitting design
- Connection type
- Size
- Material
- Manufacturer
- Applicable standard
- Temperature
- Assembly
- System duty
Do Not Select a Fitting by Appearance Alone
Two visually similar fittings may have different materials, manufacturing specifications or pressure capabilities. The complete specification should be established before a fitting is installed into a hydraulic system.
Why Do Hydraulic Fittings Leak?
A leaking hydraulic connection does not automatically mean that the fitting simply needs tightening.
Possible causes include:
- Damaged sealing face
- Damaged or incorrect O-ring or seal
- Incorrect fitting combination
- Loose connection
- Overtightening and connection damage
- Contamination on sealing surfaces
- Damaged threads
- Corrosion
- Misalignment or side loading
- Hose twist or poor routing
- Vibration
- Incorrect assembly
Repeated Leaks Need Diagnosis
If the same connection repeatedly leaks, continually tightening or replacing the same seal may not solve the underlying problem. Alignment, vibration, hose routing, damaged sealing surfaces or an incorrect connection may need investigation.
How to Identify a Hydraulic Fitting
Positive fitting identification typically requires several characteristics to be checked together.
| Check | What You Are Establishing |
|---|---|
| Thread | Thread family, form and whether it is parallel or tapered |
| Diameter | Relevant thread dimensions |
| Pitch | Spacing or threads-per-inch specification |
| Seat | Flare, cone, flat face or other sealing geometry |
| Seal | O-ring, bonded seal, seat or thread-based sealing arrangement |
| Application | Pressure, fluid, temperature, hose/tube and equipment compatibility |
For a more detailed identification guide visit Hydraulic Fittings & Adapters UK Guide.
Hydraulic Fitting Safety
Hydraulic connections can contain pressurised fluid and hydraulic systems can retain stored energy after machinery has stopped.
Never use your hand to search for a hydraulic leak. High-pressure fluid can penetrate the skin and cause a serious hydraulic injection injury.
Follow the equipment’s appropriate isolation and pressure-release procedures before disturbing hydraulic connections.
If fluid injection through the skin is suspected, seek urgent medical attention.
Hydraulic Fittings, Adapters & Hose Assemblies
Completely Hydraulic supplies hydraulic fittings, adapters and hose assemblies and supports customers who need help identifying unfamiliar hydraulic connections.
Fitting Identification
Support identifying hydraulic threads, sealing arrangements and suitable replacement connections.
Fittings & Adapters
A range of hydraulic connections for industrial and mobile hydraulic applications.
Hose Assemblies
Hydraulic hoses assembled with suitable compatible fittings and specifications.
Mobile Support
Mobile hydraulic engineering for breakdowns, hose replacement and suitable on-site hydraulic work.
Visit our trade counters in Harlow, Dagenham, Belvedere and Hayes, or contact Completely Hydraulic for mobile engineering support.
Hydraulic Fittings FAQs
What is a hydraulic fitting?
A hydraulic fitting connects hoses, tube, pipework or hydraulic components and forms part of a fluid-carrying hydraulic connection.
What are the most common hydraulic fitting types?
Common connection families encountered in UK and European hydraulic systems include BSP, JIC, ORFS and metric connections. NPT and flange connections are also found on suitable equipment.
What is a JIC hydraulic fitting?
JIC is a 37-degree flare connection. The hydraulic seal is created at the mating flare and seat surfaces rather than by the thread itself.
What is an ORFS fitting?
ORFS stands for O-Ring Face Seal. An O-ring positioned at the fitting face creates the hydraulic seal when the connection is correctly assembled.
What is a BSP hydraulic fitting?
BSP is a commonly encountered British pipe-thread family. Both parallel BSPP and tapered BSPT forms exist, so BSP should not automatically be assumed to mean a parallel thread.
Is NPT the same as BSP?
No. NPT and BSP use different thread specifications and should not be treated as interchangeable simply because some sizes can appear similar.
What is a hydraulic adapter?
A hydraulic adapter connects different sizes, orientations or connection types where the adapter is correctly specified for the system.
How do I identify a hydraulic fitting?
Identification can require the thread type, diameter, pitch, parallel or tapered form, seat geometry, sealing method and connection size to be established.
Do hydraulic fitting threads create the seal?
Not always. JIC seals at its flare surfaces, ORFS uses an O-ring face seal, and other fitting designs use their own dedicated sealing arrangements.
Why is my hydraulic fitting leaking?
Possible causes include damaged seals or sealing faces, incorrect connections, loose or overtightened fittings, damaged threads, contamination, vibration, misalignment and hose-routing problems.
Can I just tighten a leaking hydraulic fitting?
Not necessarily. Overtightening can damage a connection, while an existing leak may be caused by a damaged seal, sealing face, incorrect fitting or another problem that tightening will not solve.
Can different hydraulic fittings be mixed?
Connections should only be combined when their specifications, sealing methods, pressure capabilities, materials and application requirements are compatible.
Practical Hydraulic Advice for Your Business
Get useful hydraulic engineering information, maintenance guidance and Completely Hydraulic updates.
Related Hydraulic Fitting Guides
Need Help Identifying a Hydraulic Fitting?
Completely Hydraulic supplies hydraulic fittings, adapters and hose assemblies through our trade counters and mobile hydraulic engineering service.